In offerta

UPS ATLANTIS A03-OP1302-RC 1300VA/900W RACK 2U -DOPPIA CONVERS.SMART BATT.MANAG.INTERF. EPO -2 BATT. 12V/9A (SOST.A03 FINO:30/04

310,25

UPS ATLANTIS A03-OP1302-RC 1300VA/900W RACK 2U -DOPPIA CONVERS.SMART BATT.MANAG.INTERF. EPO -2 BATT. 12V/9A (SOST.A03
PROMO
In arrivo 10 pz il 2024-09-20

4 disponibili

COD: A03-OP1302-RC Categoria:

Descrizione

UPS ATLANTIS A03-OP1302-RC 1300VA/900W RACK 2U -DOPPIA CONVERS.SMART BATT.MANAG.INTERF. EPO -2 BATT. 12V/9A (SOST.A03

Power Rating (VA): 1300
Power Rating (W): 900

Input (Low Line Transfer):
– 80VAC-300VAC (load <=30%±5%)
– 120VAC-300VAC (load <=60%±5%)
– 140VAC-300VAC (load <=80%±5%)
– 160VAC-300VAC (load <=100%±5%)
Frequency Range: 40Hz to 70Hz
Power Factor: >0,99 (Normal Voltage)

Output
– Voltage: 208/220/230/240VAC
– AC Voltage Regulation: ±1%
– Frequency Range: 50Hz (±0.5%) or 60Hz (±0.5%)
– Waveform: Pure SineWave
– Crest Ratio: 3:1 (Max)
– Harmonic Distortion: <3% THD (liner Load) | <5% THD (Non liner Load)

Transfer:
– AC->Battery: Zero
– INV->ByPass: Less than 4ms (typical)
WaveForm (Batt. Mode): Pure Sinewave

Efficiency:
– AC Mode = 89%
– Battery = 85%
– ECO = 97%

Battery
– Voltage: 24VDC
– Capacity: 12V/9.0Ah
– Quantity: 2
– Recharge Time: 4 hours to (90%)
– Type: Sealed Maintenance Free Lead Acid VRLA Type
– Design: Easy-swappable battery design
– Charging Voltage: 27,4VDC ±1%
– Charging I: 1.0A Max

Indicators LCD Display
– UPS status | Load level | Battery level | Input/Output/battery info | Discharge time and Fault indicators

Backup Times:
– 900w up to 2:30m
– 675w up to 5:30m
– 450w up to 9 m
– 225w up to 22m

Protection:
– 105% < Overload AC <110% Overload Warning Only
– 110% < Overload AC <130% Overload Warning UPS transfers to ByPass after 1 minutes
– Overload AC >130% Overload Warning UPS transfers to ByPass after 3 seconds
– 105% < Overload Battery <110% Overload Warning Only
– 110% < Overload Battery <130% Overload Warning UPS shut down after 1 minute
– Overload AC >130% Overload Warning shut down after 3 seconds
– 110% < ByPass <120% Overload Warning UPS shut down after 30 minutes
– 120% < ByPass <130% Overload Warning UPS shut down after 10 minutes
– ByPass >130% Overload Warning UPS shut down after 1 minute
– Overload Inverter (>100%)
– Short Circuit INV: Electric Circuit
– Short Circuit AC: ICB & Electric Circuit
– Battery Over-drain Two stages: Controlled Battery Low Warning & Cut Off
– High Surge Level Immunity(>7KV)

Advanced:
– Fan detect protection and Fan speed control
– ECO mode

Connections
– Output 8 xIEC 320 C13 (Battery Power Supplied)
– RS232 and USB (HID)
– Intelligent Slot for SNMP Card
– EPO / ROO

Dimensions (WxHxD): 438 x 88 x 450 mm
Net Weight 11,5 Kg (with Battery)
Temperature: 0°-40° C
Humidity: 20-90% (non-condensing)

Recensioni

Ancora non ci sono recensioni.

Solamente clienti che hanno effettuato l'accesso ed hanno acquistato questo prodotto possono lasciare una recensione.

Ti informiamo non appena sarà nuovamente disponibile. Inserisci un email valida.